Cause of Failure / Symptoms Remedy
Friction surface wears to point of failure Order a rebuild kit, or call (716) 785-6128 to have the unit reconditioned. All ball bearings and O-Ring seals should be replaced at this time. Disk failure is easily preventable by monitoring disk wear by eye through the fan guard.
O-Ring failure Replace O-Rings, install a rebuild kit, or call (716) 785-6128 to have the unit reconditioned.
Input aire contamination Check to see that the unit is not subject to contamination of the pressurized input air. Since the inputs are conveniently located at the top of the unit, excessive oil or water in your air lines can build up in the unit and cause sluggish operation.
Clutch/brake disk contamination Clean or replace clutch/brake disk, install a rebuild kit, or call (716) 785-6128 to have the unit reconditioned. Check to see that the unit is not subject to surrounding environmental contamination or liquid contamination of the clutch/brake disk.

Specifications and Repair Instructions